The product does not have an image - the illustration shows the product category
Remote stock (3-5 days)
The item is in a remote warehouse, delivery time is 3-5 business days. More info
Delivery options - Select at checkout
Shipping @price - GLS
12,00
EUR
63,87
Incl. VAT 79,84
Total incl. delivery
94,84
Add to list
The function requires that you are logged in. Create a user and use our smart list system to keep track of future purchases, regular purchases or wish lists.
Flammable Gas Detector - Measuring Device - Model SAFE 808COM. This product is a smart detector with voice alert designed to indicate carbon monoxide leaks and all commonly occurring explosive gases in homes (natural gas, methane, propane, butane) and residential areas without significant hazard. The device is ideal for detecting gas from all domestic gas appliances, gas boilers and indicates leaks of flammable gas used for heating, cooking or warming. The SAFE 808COM is equipped with two independent sensors that do not require further calibration or a TEST button to trigger a function that allows the device to verify the operability of internal circuits using an automatic efficiency monitoring system. The device stands out for its measurement stability, high sensitivity, long life and compact size.The device is microprocessor controlled and signals CO and gas leaks both visually and acoustically via an 85 dB buzzer.
Flammable Gas Detector - Measuring Device - Model SAFE 808COM
This product is a smart detector with voice alert designed to indicate carbon monoxide leaks and all commonly occurring explosive gases in homes (natural gas, methane, propane, butane) and residential areas without significant hazard.
The device is ideal for detecting gas from all domestic gas appliances, gas boilers and indicates leaks of flammable gas used for heating, cooking or warming.
The SAFE 808COM is equipped with two independent sensors that do not require further calibration or a TEST button to trigger a function that allows the device to verify the operability of internal circuits using an automatic efficiency monitoring system.
The device stands out for its measurement stability, high sensitivity, long life and compact size.
The device is controlled by a microprocessor and signals CO and gas leaks both visually and acoustically via an 85 dB buzzer.
If the detector detects a hazard, the device triggers an audible buzzer signal accompanied by the flashing of a red "FLASH" LED and a voice alert "Please beware, carbon monoxide leak!" or "Attention, gas leak!".
With this warning message, the detector display will simultaneously show the current measured value.
This combined CO, combustible and explosive gas detector protects you and your family from two dangerous threats at the same time.
The device is powered from 230V/AC mains with a 9V NiMH battery backup in case of mains power failure (battery not included).
Function test
The device is equipped with a test function, which is used to simulate the presence of CO or gas and allows the operability of the internal circuits to be verified through an automatic efficiency monitoring system.
LCD display
Displays not only the current CO and combustible gas values, but also other additional information such as battery backup capacity via bar graph, network connection, etc. The backlit LCD display allows the low and high values of the potential hazard to be distinguished and compared.
Voice warning function
An acoustic alarm siren signal is accompanied by a human voice (in English) informing of the detected danger "Please beware, carbon monoxide leak!" or "Please beware, gas leak!".
Where to install the detector
We install combined carbon monoxide, flammable and explosive gas detectors in rooms with potential CO or gas leakage (bathrooms, gas boiler rooms, kitchens, rooms with vacuum cleaners, karma, direct-fired heaters, thermometers, etc.).
The basic criterion for the correct placement of the detector is the identification of the gas, i.e. whether we are detecting light gas (rising up to the ceiling) or heavy gas (falling to the floor).
According to this criterion we will choose the installation location. We always install the gas detector on the wall, depending on the type of gas detected, either below the ceiling (approx. 15-30 cm) or above the floor (approx. 15-30 cm), at a distance of at least 1.2 m from the fuel-burning device to minimize false alarms that may occur during a short gas leak, for example, when igniting a gas boiler or stove, and at a distance of approx. 60 cm from the corners, i.e. the place where two walls converge.
Properties of gases and their mass relative to air
Propane butane (LPG): heavier than air, sinks to the floor.
Carbon monoxide (CO), natural gas (LNG, CNG): Lighter than air, rises to the ceiling.
Petroleum substances: Heavier than air, falling towards the floor.
Ethylene: Lighter than air, rises up to the ceiling.
What is carbon monoxide?
Carbon monoxide is a colourless, tasteless and odourless gas that is produced when fossil fuels such as coal, oil, natural gas, LPG, coal and wood are burnt badly. It can also be produced by poorly maintained or faulty fuel-burning appliances used for domestic heating, such as: boilers, gas appliances, karmas, barbecues, blocked chimneys, ventilation systems or damaged flue pipes.
Common symptoms of CO poisoning include headaches, nausea, fatigue or muscle pain - but these can easily be confused with a diagnosis of flu.
What is natural gas?
Natural gas is piped into your home. Unless you live in a rural area, you probably use natural gas. It is the predominant energy for heating homes. Natural gas is a fossil fuel containing almost exclusively methane. Methane is much lighter than air and rises upward when it escapes.
If you are a natural gas user, it is recommended that you install this detection device about 30 cm from the ceiling to ensure that a gas leak is caught as quickly as possible.
What is propane?
Propane is most commonly delivered to the home in liquid form and is stored near the home in propane tanks. Propane is used in homes in rural areas where natural gas is not piped in. Since propane is the most commonly used LPG (liquefied petroleum gas), pan and LPG are often used with the same meaning. Unlike natural gas, propane is much heavier than air and stays low to the ground. It is therefore recommended that this detection device be installed low to the floor to ensure that a gas leak is caught as quickly as possible.
It is therefore important to protect your family and home with carbon monoxide and combustible gas detectors.
Advantages of the device
Unique dual combination carbon monoxide and combustible gas detection device
Voice warning - human voice informs of detected danger
Advanced catalytic combustion and electrochemical sensor technology in one device
Display of current CO and gas concentration on LCD display
Powered by AC 90V-240V mains
Backup power supply with 9V NiMH rechargeable battery in case of power failure
Intelligent detection control by microprocessor
Information and warning LED indication
Test function, verification of correct operation of the device
Self-checking detection system with automatic sensor failure indication
Backlit LCD display for displaying measured values
Loud alarm
The item is known under the following item numbers in our system
EAN:
0703123016315
SKU:
SAFE 808COM
Why do I find that the same product is available on different item numbers?
Manufacturers often release the same product with different item numbers, typically just different versions of the packaging. For example, the packaging may be targeted at different countries.
We try our best to unify the products, but it can happen that the same product appears on different item numbers in our system.