ELEKTROBOCK time switch – multifunction CS3-4M
FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
Remote stock (3-5 days)
The item is in a remote warehouse, delivery time is 3-5 business days. More info
Delivery options  - Select at checkout
Shipping @price - GLS
12,00
EUR 13,26
Incl. VAT 16,58
Total incl. delivery 31,58
Features of CS3-4M:
is a multifunctional time relay for controlling resistive (light bulbs) and inductive loads (fans) with the possibility of mounting under the switch and in wiring without a neutral wire.

Eight functions of CS3-4M:
Time delay with interrupt capability
delayed shutdown (similar to CS3-1)
Multi-time relay with interlock
time relay without interlock
pulse relay (multi-site control)
delayed tripping
Delayed ON and OFF
flasher


The great advantage is the linear time setting (coarse with the switch, fine with the trimmer), the wiring WITHOUT ZERO DRIVER and the setting of the following 8 functions.

Explanation of CS3-4M functions:
1. Time relay with interrupt capability

Load switching and timing occurs immediately after the button is pressed. By pressing the button again during timing, the load can be switched off.

2. Delayed tripping (similar to CS3-1)

The load is switched on at the moment the button is released, after timing the load is switched off.

3. Multi-time relay with interlocking
The number of presses (max. 5x) multiplies the set time. On the sixth press, the time is reset to zero. If the button is pressed for approx. 3s during timing, the load is switched off.

4. Time relay without interrupt option
Load switching and timing occurs immediately after the button is pressed. After timing, the load is switched off.

5. Impulse relay (multi-site control)
Pressing the button turns the load on and the next press of the button turns the load off. The length of the button press does not matter.

6. Delayed switching
When the button is pressed, the set time (delay) elapses, then the load is switched on, which lasts until the button is released.

7. Delayed switching on and off
When the button is pressed, the set time(delay) is delayed, followed by load switching. When the switch is released, the load is switched off with the same delay.

8. Flasher
When the button is permanently switched on, the load is switched on at set time intervals of 1:1.

Technical parameters
Power supply 230, 0 V / 50 Hz
Mounting type under the switch
Mounting without neutral wire Yes
Resistance load 5 W to 150 W
Inductive load 5 VA to 50 VA
Power input 0.500000000 W
Switching element triac
Adjustable time 1 s to 1200 min
Fuse Yes (FU 2 A/ H 520 mm)
Degree of protection IP20
Operating temperature 0 °C to 50 °C