FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
Remote stock (3-5 days)
The item is in a remote warehouse, delivery time is 3-5 business days. More info
Delivery options - Click an option to choose
Shipping @price - GLS
12,00
EUR 20,82
Incl. VAT 26,03
Total incl. delivery 41,03
Product description

The new generation of UNI-T UT131 series multimeters offers a higher standard of measurement in the more affordable category of digital multimeters. The innovative and industrial design with a protective case ensures the multimeter is shock and drop resistant from up to two meters. The new LCD display layout is clearer and more practical for all users, plus the display has a backlight option. UT131 series multimeters guarantee safe handling and measurement and are classified as CAT II safety category ( double insulated appliances ) and are designed for measurements in circuits up to 250V/AC or DC. The display range is ±1.999. Protection of the current ranges is made by fast tubular fuses ( 10A range by 10A/250V fuse; mA/µA range by 200mA fuse ). The power supply of the multimeter is made by two AAA 1,5V alkaline batteries.

The UT131A model in the UT131 series features automatic selection of the measurement range within a given measurement Vst, Vss, mVss/st , resistance, buzzer, semiconductor, µAss/st, mAss/st , Ass/st and in addition capacitance measurement of capacitors in the range 2nF to 2mF.

Product Parameters :

- Display range ±1.999
- measures parameters Vst, Vss, mVss/st , µAss/st , mAss/st , Ass/st, resistance, capacitance, throughput (buzzer), semiconductor transitions (diodes)
- automatic range selection
- DC voltage measurement : 200 mV to 250 V
- AC voltage measurement : 200 mV to 250 V
- DC current measurement : 200.0 µA to 10.00 A
- Alternating current ( AC ) measurement : 200.0 µA to 10.00 A
- Resistance measurement : 200.0 ? to 200.0 M?
- Capacitor capacitance measurement : 2.000 nF to 2.000 mF
- CAT II safety category (double insulated) up to 250V AC/DC
- Power supply with 2x AAA 1.5V alkaline batteries
- backlit display
- Line continuity test (buzzer)
- diode test
- reverse polarity detection
- Data hold function
- low battery indication
- automatic shutdown after 15 min. of inactivity
- measuring cables included

Technical parameters :

DC voltage measurement ( input impedance approx. 10M? ) :
(range / resolution / accuracy)
200 mV / 0.1 mV / ± 0.7% + 3
2000 mV / 1 mV / ± 0.5 % + 2
20.00 V / 0.01 V / ± 0.7 % + 3
200.0 V / 0.1 V / ± 0.7 % + 3
250 V / 1 V / ± 0.7 % + 3

AC voltage measurements ( input impedance approx. 10M?, 40Hz to 400Hz sine ) :
(range/resolution/accuracy)
200.0 mV / 0.1 mV / ± 1.0% + 2
2.000 V / 0.001 V / ± 0.7% + 3
20.00 V / 0.01 V / ± 1.0 % + 2
200.00 V / 0.1 V / ± 1.2 % + 3
250 V / 1 V / ± 1.2 % + 3


DC current measurement :
(range/resolution/accuracy)
200.0 µA / 0.1 µA / ± 1.0% + 2
2000 µA / 1 µA / ± 1.0% + 2
20.00 mA / 0.01 mA / ± 1.0 % + 2
200.0 mA / 0.1 mA / ± 1.0 % + 2
2.000 A / 0.001 A / ± 1.2 % + 5
10.00 A / 0.01 A / ± 1.2 % + 5


AC current measurement ( 40Hz to 400Hz sine wave ) :
(range / resolution / accuracy)
200.0 µA / 0.1 µA / ± 1.2% + 3
2000 µA / 1 µA / ±1.2% + 3
20.00 mA / 0.01 mA / ±1.2 % + 3
200.0 mA / 0.1 mA / ±1.2 % + 3
2.000 A / 0.001 A / ± 1.5 % + 5
10.00 A / 0.01 A / ± 1.5 % + 5


Resistor resistance measurement :
(range/resolution/accuracy)
200.0 ? / 0.1 ? / ± 1.0 % + 2
2000 ? / 1 ? / ± 0.8 % + 2
20.00 k? / 0.01 k? / ± 0.8 % + 2
200.0 k? / 0.1 k? / ± 0.8 % + 2
20.00 M? / 0.01 M? / ±1.2 % + 3
200.0 M? / 0.1 M? / ± 5.0 % + 10

Capacitance measurement of capacitors :
(range/resolution/accuracy)
2.000 nF / 0.001 nF / in REL mode ± 5% + 5
20.00 nF / 0.01 nF / ± 4 % + 8
200.0 nF / 0.1 nF / ± 4 % + 8
2.000 µF / 0.001 µF / ± 4 % + 8
20.00 µF / 0.01 µF / ± 4 % + 8
200.0 µF / 0.1 µF / ± 4 % + 8
2000 µF / 0.001 µF / ± 10 %

The instrument complies with IEC 61010-1, IEC 61010-2-030, CAT II standards
Power supply : 2 x AAA 1.5 V batteries
Dimensions (mm) : 134 x 77 x 47
Weight : approx. 206 g (including batteries)
Operating temperature : 0 - 40°C
Manufacturer : UNI-TREND
www.uni-t.cz

Package contents :

- UNI-T UT131A Multimeter
- measuring cables
- batteries 2 x AAA, 1,5V